Live wall diagram
Drawn from your wall length, spacing, wall ends and openings — not a stock image.
Home / US Calculators / Framing Calculator
Home & Building
A production-grade stud wall calculator: enter your wall length, height, on-center spacing, corners and openings to get an exact stud count, precut cut length and top/bottom plate lumber, plus a live wall diagram that redraws itself from your own numbers.
Studs to buy
27 studs
Live wall diagram
Drawn from your wall length, spacing, wall ends and openings — not a stock image.
Stud count breakdown
Where the total stud count comes from.
Framing a wall comes down to four numbers: how many field studs the on-center spacing calls for, how many extra studs each corner needs, how many extra studs each door or window opening needs, and a waste allowance for cutting mistakes and damaged lumber. This is the same method framers and estimators use to build a material take-off, not a rough per-foot guess.
Convert wall length to inches, divide by your spacing (16" O.C. is the US standard; 24" O.C. is common for single-story advanced framing), then add 1 for the stud that starts the run.
Each corner needs a 3-stud post so both intersecting walls have drywall backing, which is 2 studs more than the single field stud already counted at that end. A 2-stud "California corner" saves one stud and adds insulation space, but isn't universal — check your local code.
Every door or window rough opening needs 2 full-height king studs and 2 shorter jack (trimmer) studs that carry the header's load down to the plate, 4 studs per opening. Cripple studs above the header are typically cut from stud offcuts, so most estimators don't add them as separate lumber.
Add 5-10% on top of the raw total to cover crooked or split studs, cutting errors, and last-minute design changes, then round up to a whole stud.
A 20 ft wall, 8 ft tall, framed 16" O.C. with corners at both ends and one door opening: field studs = floor(240 ÷ 16) + 1 = 16. Corners add 2 × 2 = 4. The opening adds 4 more. That's 24 studs before waste; with a 10% allowance, ceil(24 × 1.10) = 27 studs. Each stud is cut to 96" − 4.5" = 91.5" (91-1/2"). The three plate courses need 20 ft × 3 = 60 linear ft of lumber, or four 16-ft boards after a small seam allowance.
Every wood-framed wall is built from a handful of stud types, each doing a different structural job. The diagrams below highlight one member at a time against the rest of the same opening, drawn in scale to real IRC-style framing, not stock photography.
The full-height stud repeated at every on-center spacing mark — 16" or 24" apart — that makes up most of a wall.
Full-height studs on both sides of a rough opening, running plate to plate, that the header hangs from.
Shorter studs nailed to the inside of each king stud, cut to the rough opening height, that carry the header's load to the plate.
Short filler studs above a header (and below a window sill), spaced on the same layout as the field studs but cut shorter.
Three studs grouped where two walls meet (plan view above), giving nailing backing for exterior sheathing and interior drywall on both faces.
Where an interior wall meets a continuous wall, extra studs form a "T" so both sides of the partition have drywall backing too.
Field studs from wall length ÷ spacing + 1, plus 2 per corner and 4 per opening, then round up 5-10% for waste.
16" O.C. is the traditional standard sized to 4x8 sheet goods; 24" O.C. uses about a third fewer studs and is allowed for many single-story walls under advanced framing, subject to your local code.
A standard 3-stud corner adds 2 studs beyond the field stud already counted; a 2-stud California corner adds only 1.
4: two full-height king studs plus two jack (trimmer) studs. Cripples are usually cut from offcuts.
91.5" for a single bottom plate and doubled top plate. Lumber yards commonly stock a 92-5/8" precut stud instead.