Plan a timber partition the way UK joiners do: set the wall length and height in metres, choose 400mm or 600mm centres to suit your plasterboard, add corners and door openings, and get the stud count, cut length and plate timber, with a wall diagram drawn from your figures.
Studs to buy
21 studs
Live wall diagram
Drawn from your wall length, centres, wall ends and openings — not a stock image.
Stud count breakdown
Where the total stud count comes from.
In UK studwork the timber list is driven by the plasterboard. Boards come 1200mm wide, so studs have to land at centres that divide neatly into 1200mm, which is why 600mm and 400mm are the only spacings you will see on drawings. Once the centres are fixed, the stud count follows from the wall length, the number of corners and junctions, and the number of door or window openings, plus a margin for timber you cannot use.
Work in millimetres. Divide the wall length by the centres and add one for the first stud. At 600mm, every 2.4m of wall needs four studs plus the starter; at 400mm it needs six. Use 600mm for ordinary non-load-bearing partitions lined with 12.5mm board, and drop to 400mm for 9.5mm board, tiled walls, walls that will carry heavy kitchen units, or anywhere your building control officer or engineer asks for it.
Where two walls meet at a corner, the board on the inside face needs something to fix to. A three-stud corner post gives that, which means two studs beyond the one already counted. Where a new partition butts into an existing masonry wall, you usually only need a single stud plugged and screwed to the brickwork, so you can set the corner count to zero at that end.
A door opening is framed with a full-height stud each side (king studs) and a second, shorter stud inside each (jack or trimmer studs) that supports the head. That is four studs per opening. Above the head, short noggins on the stud layout carry the board up to the head plate; most joiners cut these from offcuts rather than buying extra lengths.
Merchant timber is not always straight. Allow 5% for good-quality regularised CLS and closer to 10% for sawn carcassing, where you will reject the odd twisted or shaken length. Round the total up to a whole stud.
A 6 m wall, 2.4 m tall, framed at 600mm centres with corners at both ends and one door opening: field studs = floor(6000 ÷ 600) + 1 = 11. Corners add 2 × 2 = 4. The opening adds 4 more. That's 19 studs before waste; with a 10% allowance, ceil(19 × 1.10) = 21 studs. Each stud is cut to 2400mm − 135mm = 2265mm. The three plate runs need 6 m × 3 = 18 linear metres of timber, or six 3.6 m lengths after a small seam allowance.
A typical UK partition uses six kinds of timber member. Each drawing below picks out one of them, shown in its place around a door opening, so you can match the names on a joinery drawing or a builders' merchant quote to the pieces on site.
The upright that repeats along the wall at 400mm or 600mm centres, usually 38 × 63mm or 38 × 89mm CLS for partitions.
Runs unbroken from sole plate to head plate either side of a door, and is the stud the door lining is ultimately fixed through.
Nailed or screwed against the king stud and cut to the height of the opening, so the head timber sits on top of it.
Short lengths above the door head, kept on the stud centres so every board edge has fixing. Horizontal noggins between studs are also used at board joints and behind radiators, basins and wall-hung TVs.
Three studs arranged in plan so both the inside and outside board faces have something solid to screw into at the corner.
Where one partition runs into the middle of another, two extra studs either side of the junction give the boards on both sides a fixing.
Most internal partitions in UK homes are built from CLS (Canadian Lumber Standard) timber: kiln-dried, planed, with rounded edges, sold in 38 × 63mm and 38 × 89mm sections. It is straighter and easier to handle than sawn carcassing, and is the default at most builders' merchants. Structural walls and anything carrying a floor or roof load are normally designed in graded timber, C16 or the stronger C24, often 47mm thick, with sizes set by an engineer.
| Section | Typical use | Notes |
|---|---|---|
| 38 × 63mm CLS | Non-load-bearing partitions up to about 2.4m high | Light and cheap; leaves a 63mm void for insulation |
| 38 × 89mm CLS | Taller partitions, walls with heavy fixings, better sound insulation | Stiffer; takes 89mm mineral wool |
| 47 × 100mm C16/C24 | Load-bearing studwork, timber frame | Sized by an engineer for the load |
Timber is sold in set lengths, usually 2.4m, 3.0m, 3.6m, 4.2m and 4.8m. For a standard 2.4m room height, a 2.4m length gives one stud with nothing left over once the plates are deducted, so check whether your cut length (2265mm in the worked example) fits your merchant's stock before ordering. Plates are cheapest bought in the longest lengths you can transport.
A simple non-load-bearing partition inside a house does not usually need Building Regulations approval in England and Wales. Several situations do bring it in:
Rules in Scotland and Northern Ireland are set separately. When in doubt, a short call to your local building control team before you start is free and can save a lot of rework.
Lightweight steel stud systems are common in commercial fit-outs and increasingly in homes. Metal studs are perfectly straight, do not shrink or twist, and are quick to cut and assemble with track at the floor and ceiling. Timber is still easier for a DIY builder to fix into, handles heavy items like kitchen cabinets with simple screws, and needs no special tools. The stud count is similar either way; metal systems use the same 600mm or 400mm centres, so the calculator still applies, although the corner and opening details follow the manufacturer's guide.
Standard boards are 2400 × 1200mm, which covers 2.88 m². The 6m × 2.4m wall in the worked example has 14.4 m² on each face, so lining both sides takes 28.8 m², or exactly 10 boards. Add one or two for the door opening offcuts and damage, and remember the area of the opening itself is a small saving, not a full board. For other area and conversion sums, the area converter helps.
At 600mm centres a 6m wall needs 11 studs along its length. A three-stud corner at each end adds 4 and a door opening adds 4, so 19 in total, or 21 once you add 10% for waste. At 400mm centres the same wall needs 16 studs along its length.
600mm is standard for non-load-bearing partitions lined with 12.5mm plasterboard. Use 400mm for 9.5mm board, walls that will be tiled or carry heavy units, or where a structural engineer or building control specifies it.
Most domestic partitions use 38 x 63mm or 38 x 89mm CLS timber. Load-bearing studwork is normally C16 or C24 graded timber, often 47mm thick, sized by an engineer.
A simple non-load-bearing partition usually does not. Approval is needed for load-bearing walls, walls that form part of a fire escape route, and some new walls with sound insulation requirements, such as around bedrooms.
With a 45mm sole plate and a doubled 90mm head plate, studs are cut to 2265mm. With a single head plate, which is common for non-load-bearing partitions, they would be 2310mm.